O. K. Tokovoi.
ABSTRACT:
Using modeling method and experiments at industrial 100-ton AOD refining unit the mass transfer coefficients of main components of stainless steel (carbon, chromium, sulfur, and nitrogen) were determined. The results obtained on a model are in satisfactory agreement with data obtained on an industrial unit, and may be used in the mathematical model of molten steel processing in automatic control unit of AOD.
KEY WORDS:
AOD refining unit, stainless steel, mass transfer coefficient of carbon, sulfur, chromium, nitrogen.