Influence of weather conditions on aluminum work indicators of electrolysis of Kazakhstan electrolysis factory

V. A. Lebedev, Zh. Zh. Kamzin

ABSTRACT

According to the average monthly data of OA “KEZ” from January 2010 until March 2011 for two series of electrolysis, working at the plant, a regression analysis of the dependences of the average voltage, current yield, specific consumption of electricity from the water vapor pressure in atmospheric air (P) was performed. Increase in P by 10 mm Hg does not affect the amount of working interference, increases the current efficiency by 0.48– 0.63%, reduces the specific power consumption by 73–78 kW • h/t. The observed regularities are explained by a decrease in the fluorine content in flowing into the cryolite-alumina melt of alumina by the removal of desorbed hydrogen fluoride with water vapor in the presence of fluorinated alumina in the range of APG punching.

KEYWORDS:

fluorinated alumina, fluorine content, water vapor pressure, average voltage, current efficiency, specific power consumption, regression analysis

DOI: 10.1134/S0235010619020026

Posted in metallurgy, recycling and refining of metals, металлургические процессы.